TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11802 Check if harnes between terminal #C24 of harness end of connector MC-C in MC and terminal #2 in boom bottom pressure sensor is open or shorted. YES Faulty harness between MC and boom bottom pressure sensor. YES Disconnect connector of boom bottom pressure sensor. Check fi voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. NO Faulty MC. NO Open circuit in harness between MC and boom bottom pressure sensor (terminal #3). Switch boom bottom pressure sensor and pump 2 delivery pressure sensor. Check if fault code disappears .
Check fi voltage between terminal #1 of harness end of connector in boom bottom pressure sensor and machine is specification. YES · Key switch: ON NO Open circuit in harness between MC and boom bottom pressure sensor (terminal #1). · Key switch: ON · Refer to the table upward. NO YES Faulty boom bottom pressure sensor. Connector (Harness end of connector viewed from the open side) Boom Bottom Pressure Sensor (Arm Roll-In) MC Connector MC-C C1 C10 C23 C31 T1J1-05-06-001 #C24 T5-6-77 Fault Code Trouble Cause 11802-3 Abnormal Boom Bottom Pressure Sensor High Voltage Voltage: 4.5 V or higher 11802-4 Abnormal Boom Bottom Pressure Sensor Low Voltage Voltage: Less than 0.25 V