TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11901 Connect terminals #1 and #2 of harness end of connector in hydraulic oil temperature sensor by using a clip. Disconnect connector MC-D from MC. Check for continuity between terminals #D2 and #D6 of harness end of connector MC-D. YES Faulty MC. Open circuit in harness between MC and hydraulic oil temperature sensor (terminal #1). Disconnect connector of hydraulic oil temperature sensor. Check if resistance at sensor end connector is specification. YES Connect terminal #D6 of harness end of connector MC-D in MC to machine.
Check for continuity between terminals #2 of harness end of connector in hydraulic oil temperature sensor and machine. YES NO NO Open circuit in harness between MC and hydraulic oil temperature sensor (terminal #2). · Specification: Refer to the table below. Faulty hydraulic oil temperature sensor. Specification of Hydraulic Oil Temperature Sensor NO Connector (Harness end of connector viewed from the open side) T183-05-04-009 T5-6-78 Fault Code Trouble Cause 11901-3 Hydraulic Oil Temperature Sensor High Voltage Intake Air Temp.: 21 °C or higher Voltage: 4.10 V or higher The above condition holds 30 seconds or more. 11901-4 Hydraulic Oil Temperature Sensor Low Voltage Voltage:
Less than 0.23 V The above condition holds 30 seconds or more. Hydraulic Oil Temperature (°C) Resistance (kΩ) -20 16.2±1.6 0 (5.88) 20 2.45±0.24 40 (1.14) 60 (0.534) 80 0.322 MC Connector MC-D MC-D #D2 #D6 #D6 Hydraulic Oil Temperature Sensor 1 2