TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11999 Connector (Harness end of connector viewed from the open side) Pilot Pressure Sensor (Bucket Roll-In) MC Connector MC-C #C2 C1 C10 T1J1-05-06-001 C23 C31 T5-6-92 Fault Code Trouble Cause 11999-3 Abnormal Bucket Roll-In Pilot Pressure Sensor High Voltage Voltage: 4.75 V or higher 11999-4 Abnormal Bucket Roll-In Pilot Pressure Sensor Low Voltage Voltage: Less than 0.25 V Check if harnes YES Faulty harness between between terminal #C2 MC and pressure sensor. of harness end of YES connector MC-C in MC and terminal #2 in pressure sensor is Faulty MC. open or shorted. Disconnect connector NO of pressure sensor.
Check fi voltage NO between terminals #1 and #3 of harness end Open circuit in harness of connector is 5±0.5 between MC and V. YES pressure sensor (terminal Check fi voltage · Key switch: ON #3). between terminal #1 of harness end of Switch pressure sensor NO connector in pressure with other pressure sensor and machine is Open circuit in harness sensor and retry. specification. between MC and Check if fault code NO pressure sensor (terminal disappears. · Key switch: ON #1). · Refer to the table upward. Faulty pressure sensor. YES YES Faulty harness between MC and pressure sensor. Faulty pressure sensor. Disconnect connector of pressure sensor.
Check fi voltage between terminals #1 NO and #3 of harness end of connector is 5±0.5 V.