hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 20062 Fault Code Trouble Cause 20062-0 Hydraulic Oil Overheat Alarm Hydraulic Oil Temperature: 100 ° C or higher If the sensor corresponding to overheat prevention control is abnormal, MC activates the fan pump control solenoid valve and flow rate of fan pump becomes maximum. Therefore, if this fault code only is displayed, the related sensor should not be abnormal. If other fault code is displayed, perform the diagnosing procedure for the displayed fault code first. When the engine starts or when the hydraulic oil tank is cold, if this fault code is displayed, MC is faulty. NO YES Faulty oil cooler bypass check valve.

Check if fan speed is normal. YES Faulty fan pump, Faulty fan pump regulator, or incorrect fan installation. Clean oil cooler. Retry by using Dr. ZX. NO Check if drain amount of fan motor is normal. Faulty fan motor. NO YES End (Clogged oil cooler). T5-6-93