TROUBLESHOOTING / Troubleshooting B T5-7-15 Boom Flow Rate Control Valve Arm Flow Rate Control Valve Bypass Shut-Out Valve (4-Spool Side) • Restricts boom lower circuit when operat- ing boom lower and arm or boom lower and bucket, so that other actuator speed increases. • Restricts arm roll-in circuit during combined operation of boom raise and arm roll-in, so that boom raise speed increases. • Supplies pressure oil from pump 1 to auxiliary spool when auxiliary spool is operated. • If control valve is bound at fully closed, boom raise speed is slow. • If control valve is bound at fully open, arm speed is slow during combined operation of boom lower and arm.
• If control valve is bound at fully open, bucket speed is slow during combined op- eration of boom lower and bucket. • If control valve is bound at fully closed, arm roll-out speed is slow. • If control valve is bound at fully open, boom raise speed is slow during combined operation of boom raise and arm roll-in. • If spool is bound at fully open, single attachment operation speed be- comes slow. • If spool is bound at fully closed, main relief valve continues to relieve with all control levers positioned in neu- tral. • When all control levers are in neutral, pump 1 pressure is higher than pump 2 pressure according to the spool bound conditions.
• If control valve is bound at fully closed, boom raise speed is slow. • If control valve is bound at fully open, arm speed is slow during combined operation of boom lower and arm. • If control valve is bound at fully open, bucket speed is slow during combined op- eration of boom lower and bucket. • If control valve is bound at fully closed, boom raise speed is slow. • If control valve is bound at fully open, boom raise speed is slow during combined operation of boom raise and arm roll-in. • If spool is bound at fully open, single attachment operation speed be- comes slow.
• If spool is bound at fully closed, main relief valve continues to relieve with all control levers positioned in neu- tral. • When all control levers are in neutral, pump 1 pressure is higher than pump 2 pressure according to the spool bound conditions. - - - - - - - - - - - - - - - T2-1, 3-3 T2-4 T3-3