TROUBLESHOOTING / Troubleshooting B T5-7-17 Boom Anti-Drift Valve Arm Anti-Drift Valve Flow Combiner Valve Control Spool • Forcibly open check valve in boom lower return circuit and allows boom to move only when boom is lowered. Prevents boom from drifting due to oil leaks in control valve. • Forcibly open check valve in arm roll-in return circuit and allows arm to move only when arm is rolled in. Prevents arm from drifting due to oil leaks in control valve. • Be shifted by right travel pilot pres- sure and supplies control pressure to flow combiner valve in control valve. • If switch valve is bound, check valve does not open. • If switch valve is bound, check valve does not open.
• If spool is bound at fully open, when boom, arm, bucket or swing and travel is operated, flow combiner valve is shifted. • If spool is bound at fully closed, when combined operation of travel and front/swing is made, machine mis- tracks to the left. (Left travel speed becomes slow.) • If check valve is kept closed, boom does not lower. • If check valve is kept open, front attach- ment drift increases due to oil leaks in con- trol valve. • Boom moves jerky or boom speed be- comes slow depending on valve bound conditions. • If check valve is kept closed, arm roll-in speed becomes slow. • If check valve is kept open, front attach- ment drift increases due to oil leaks in con- trol valve.
• Arm moves jerky or arm speed becomes slow depending on valve bound conditions. • If spool is bound at fully open, when boom, arm, bucket or swing and travel is operated, flow combiner valve is shifted. • If spool is bound at fully closed, when combined operation of travel and front/swing is made, machine mis- tracks to the left. (Left travel speed becomes slow.) - - - - - - - - - - - - - - - T 3-3 T3-3 T3-6