hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B E-5 Faulty HP mode Even if power mode switch is turned to the HP mode position, HP mode is inoperable. (General mode normally operates.) The sensors detect the conditions necessary to operate HP mode. Therefore, if any of these sen- sors fails, HP mode becomes inoperable. Pressure sensors (arm roll-in and boom raise) and pump 1 and 2 delivery pressure sensors are also engaged in the HP mode control. However, if these sensors fail, other operating functions will be also affected. Refer to the pages for HP Mode Control in the SYSTEM / Control System group in the T/M (Op- erational Principle). Check the wiring connections first.

Faulty power mode switch or open circuit in harness between power mode switch and MC. NO Monitor power mode switch. Check if indication HP is highlighted when power mode switch is turned to “HP mode”. NO Faulty MC. · Monitor item: HP mode switch YES Check if fault code is displayed. T5-7-42 Related Fault Code Trouble Reference Page MC 11004 CAN Communication Error T5-6-28 11200 Abnormal Pump 1 Delivery Pressure Sensor T5-6-50 11202 Abnormal Pump 2 Delivery Pressure Sensor T5-6-51 11302 Abnormal Boom Raise Pilot Pressure Sensor T5-6-53 11303 Abnormal Arm Roll-In Pilot Pressure Sensor T5-6-54 Refer to Troubleshooting A. YES