TROUBLESHOOTING / Troubleshooting B E-7 Faulty auto-idle system Even if control lever is turned to neutral, auto-idle system is inoperable. In case trouble symptoms E1 to E6 are recog- nized, perform the troubleshooting of these trou- bles first. Even if failure in each pilot pressure sensor may have relevance to malfunction of the auto-idle control. However, if these sensors fail, other op- erating functions will also be affected. Connector (Harness end of connector viewed from the open side) Refer to the pages for Auto-Idle Control in the SYSTEM / Control System group in the T/M (Op- erational Principle). Check the wiring connections first. YES Faulty MC. YES Monitor auto-idle switch.
Switch auto-idle switch. Check if ON-OFF is changed. Open circuit in harness between auto-idle switch and MC. · Monitor Item: Auto-idle switch Check if Auto-Idle is displayed on monitor unit. NO YES Faulty auto-idle switch. · Auto-idle switch: ON Disconnect connector moni- tor-B. Check for continuity between terminal #B18 of harness end of connector and ma- chine. NO Open circuit in harness between auto-idle switch and monitor unit. NO · Auto-idle switch:
ON Connector Monitor-B #B18 T5-7-46 Related Fault Code Trouble Reference Page MC 11004 CAN Communication Error T5-6-28 11301 Abnormal Swing Pilot Pressure Sensor T5-6-52 11302 Abnormal Boom Raise Pilot Pressure Sensor T5-6-53 11303 Abnormal Arm Roll-In Pilot Pressure Sensor T5-6-54 11991 Abnormal Right Travel Pilot Pressure Sensor T5-6-68 11993 Abnormal Left Travel Pilot Pressure Sensor T5-6-70 11995 Abnormal Arm Roll-Out Pilot Pressure Sensor T5-6-72 11997 Abnormal Bucket Roll-Out Pilot Pressure Sensor T5-6-73 11998 Abnormal Boom Lower Pilot Pressure Sensor T5-6-74 11999 Abnormal Bucket Roll-In Pilot Pressure Sensor T5-6-75 ECM 639 Abnormal CAN T5-6-18, 19 6 5 20 19 18 17 16 15 14 13 12 11