TROUBLESHOOTING / Troubleshooting B ALL ACTUATOR SYSTEM TROUBLE- SHOOTING A-1 All actuator speeds are slow. Check the wiring connections first. Connector (Harness end of connector viewed from the open side) YES Faulty pilot shut-off relay (R2). YES Switch pilot shut-off relay (R2) with other general relay. Check if fault code is improved. YES Faulty security relay (R5). Switch security re- lay (R5) with other general relay. Check if fault code is improved. Disconnect con- nector of pilot shut-off solenoid valve. Check if voltage at terminal #2 of har- ness end of con- nector is 24 V. NO A Monitor pilot shut-off switch. Check if ON is changed. NO · Monitor Item (MC):
Gate lock switch · Pilot shut-off lever: UNLOCK position · Key switch: ON Faulty pilot shut-off switch. NO Disconnect connector of pilot shut-off solenoid valve. Check for continuity between terminals #1 and #2 of solenoid valve end of connector. YES Faulty monitor unit. YES Faulty pilot shut-off solenoid valve. NO A Faulty fuse #4 or open circuit in harness be- tween fusible link (75 A) and pilot shut-off solenoid valve. NO Pilot Shut-Off Solenoid Valve Pilot Shut-Off Solenoid Valve (So- lenoid Valve End) T183-05-04-010 T1J1-05-07-006 T5-7-54