hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B A-2 All actuator speeds are slow. Reduction in pump 1 and 2 flow rate due to some reasons or faulty pilot system may cause this trouble. Although speed is satisfactory, in case power is weak, refer to the troubleshooting faulty relief valve (F-1). As for the machine equipped with the counter- weight removal / installation device (optional), check the pilot pressure (counterweight). Check the wiring connections first. Check if primary pilot pressure is normal. · Specification: Refer to Operational Perform- ance Test. · Fully boom raised or arm roll-in · Monitor item:

Boom raise pilot pressure, arm roll-in pilot pres- sure T5-7-55 Faulty pilot pump or YES clogged pilot filter. Check if same symptom still ap- NO pears after disas- sembling, cleaning, and adjusting pilot End. relief valve. NO YES Refer to Engine Troubleshooting Manual. Monitor actual en- gine speed. Check if abnormal NO Faulty main relief YES speed is indicated. valve. · Monitor item: Engine actual speed Check if main relief · Possible to display by pressure is normal. NO using built-in diag- nosing system · Refer to Operational Performance Test Faulty Pump device. for pressure meas- YES urement procedure. Faulty pilot pump or clogged pilot filter. Faulty Pump device.

YES NO Faulty main relief valve.