hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B A-4 Right travel is inoperable during single travel operation. Single bucket operation speed is slow. Boom is not raised properly during arm level crowding. (All problems occur at the same time.) The pump 1 flow rate is minimized due to some reasons. Accordingly, the right travel motor and bucket cylinder, which are actuated by pressure oil from pump 1, moves very slow. Pressure oil from pump 2 is also routed to the arm and boom cylinders so that the arm and boom can move at a slightly slow speed in single operation. However, in level crowd operation, pressure oil is routed to the arm prior to the boom so that boom is scarcely raised.

Check the wiring connections first. Refer to the SYSTEM / Hydraulic System group in the T/M (Operational Principle). YES Faulty pump 1 delivery pressure sensor. Check if any fault codes are dis- played. Switch pump 1 delivery pressure sensor with pump 2 delivery pres- sure sensor. Check if symptom is improved. NO Faulty pump 1. Monitor pump 1 deliv- ery pressure with con- trol lever in neutral. Check if pressure is minimum. When operating con- trol lever, check if pump 1 delivery pres- sure is changed. NO · Right travel Operation YES Faulty pump 1 regulator pressure sensor. Switch pump 1 regulator pressure sensor with pump 2 regulator pres- sure sensor. Check if symptom is improved.

NO · Monitor item: Pump 1 delivery pressure · Control lever operation: Except left travel and swing Monitor pump 1 regulator pres- sure. Check if pressure with con- trol lever in neutral is changed to pressure when operating control Stuck pump 1 control solenoid valve or faulty MC. · Right travel Operation NO YES · Monitor item: Pump 1 regulator pressure · Jack up right track and fully operate right travel control lever. Faulty pump 1 regulator. YES T5-7-57