hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B FRONT ATTACHMENT SYSTEM TROU- BLESHOOTING F-1 All front attachment actuator power is weak. In case operating speeds are extremely slow, pump control may be malfunctioning (A-1 and/or A-2). Faulty pilot system may also cause this trouble. 31.9 to 34.3 MPa (325 to 350 kgf/cm 2 , 4640 to 4990 psi) Main relief valve should be normal. Find out cause of trouble by tracing other trou- ble symptoms. Monitor pump 1 and 2 delivery pressures. · Monitor item: Pump 1 and 2 delivery pressure · Possible to display by using built-in diagnosing system · Relieve boom, arm and bucket circuits. · Power mode switch: HP · Work mode: Digging Adjust main relief valve.

Less than 31.9 MPa (325 kgf/cm 2 , 4640 psi) T5-7-64