hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B F-2 Even if power digging switch is pushed, power does not increase. Boom raise power is week when digging. Reference Page T5-6-53 MC T5-6-57 Refer to the pages for the SYSTEM / Power Dig- ging Control group in T/M (Operational Principle). YES Refer to Trouble- shooting A. Check if fault code is displayed. Faulty power digging switch, or open cir- cuit in harness be- tween power digging switch and MC. NO Monitor Power digging switch. When pushing power digging switch, check if ON is displayed. Monitor main relief control pressure. Check if pressure is approx. 3.9 MPa (40 kgf/cm 2 , 570 psi) NO YES Faulty main relief valve. · Monitor item:

Power digging switch · Possible to display by using built-in diagnos- ing system YES Faulty MC. · Monitor item: Main relief pressure control valve output · Possible to display by using built-in diagnosing system NO T5-7-65 Trouble 11302 Abnormal Boom Raise Pilot Pressure Sensor 11404 Abnormal Solenoid Valve Unit (SG)