hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B F-3 Some cylinders are inoperable or speeds are slow. When other actuators (travel and swing motors) operate normally, the pilot pump (primary pilot pressure) is considered to be normal. Refer to F-6 if boom lowering is slow. NO Bound control valve spool or faulty cylinder (faulty seal kit). YES Check if overload relief pressure is normal. Monitor pump control pressure. Check if pump control pressure changes smoothly while mov- ing control lever slowly. YES YES Faulty overload relief valve. NO Monitor or measure secondary pilot pres- sure. Check if secondary pi- lot pressure is normal. · Monitor item:

Pump 1 flow control pressure, pump 2 flow control pressure · Possible to display by using built-in diagnosing system Faulty shuttle valve in signal control valve. NO · Secondary pilot pressure: Refer to Operational Per- formance Test. · Monitor item: Boom raise pilot pressure (Possible to display by using built-in diagnosing system), boom lower pilot pres- sure, arm roll-in pilot pressure (Possible to display by using built-in diagnosing system), arm roll-out pilot pressure, bucket roll-out pilot pres- sure, bucket roll-in pilot pres- sure (Possible to display by using built-in diagnos- ing system) Faulty pilot valve or bound shockless valve spool (during abnormal boom op- eration). T5-7-66