hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B F-6 Even if the boom mode selector switch is pushed, machine is raised off ground. Reference Page T5-6-67 Refer to the pages for Boom Mode Selector Con- trol in SYSTEM / Control System group in T/M (Operational Principle). Check the wiring connections first. Connector (Harness end connector viewed from the open end side) Disconnect boom mode selector switch and con- nector B in MC. Check for continuity be- tween terminal #9 of harness end connector of boom mode selector switch and terminal #2 of harness end connector B in MC. YES Faulty MC. NO Open circuit in har- ness between con- nector B in MC and boom mode selector switch.

Exchange boom mode selector switch with level check switch. Check if system operates properly. NO NO Monitor boom mode selector switch. Check if ON is dis- played. YES Faulty boom mode selector switch. · Monitor item: Boom mode switch NO Faulty MC. Faulty boom overload relief valve or boom overload control valve in control valve. YES · Monitor item: boom mode control valve output. · Boom mode selector switch: ON · Boom lower operation Boom Mode Selector Switch MC Connector B #2 B1 B8 T1J1-05-07-003 #9 B19 B25 T5-7-69 Trouble 11984 Abnormal Solenoid Valve Unit (SC) Monitor solenoid valve unit (SC). Check if pressure is YES approx. 3.9 MPa (40 kgf/cm2, 570 psi).