hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B F-7 When boom raise or arm roll-out is operated, boom or arm starts to move after moving slightly downward. Damaged control valve spool, broken spring, or loose spool end. Check if excessive cylinder internal leak- age is found. NO YES Faulty cylinder seal. Check if load check valve in control valve is normal. YES · Disassemble / visual inspection NO Faulty Load check valve . NOTE: 1. During the initial stage of operation, oil pressure and flow rate from the pump is low. Therefore, if the load check valve is malfunctioning, the oil in the bottom side of the boom cylinder flows back into the circuit through the load check valve.

Therefore, the boom cylinder is tempo- rarily retracted. 2. As oil pressure and flow rate from the pump is low, if oil leaks from bottom side (A) to rod side (B) due to faulty boom cylinder piston or cylinder barrel, the boom cylinder is temporarily retracted during the initial stage of operation. In addition, when cylinder force is reduced, the cylinder drift increases in this case. (B) When the load check valve is faulty: (A) T105-07-04-012 T5-7-70