TROUBLESHOOTING / Troubleshooting B F-8 Front attachment drifts remarkably. Boom Cylinder Internal Leakage Check 1. With the bucket cylinder fully retracted and the arm cylinder slightly extended from the fully re- tracted position, lower the bucket tooth tips onto the ground. measurement pro- cedure. 2. Disconnect hoses from the boom cylinder rod side. Drain oil from the hoses and cylinders. (Plug the disconnected hose ends.) 3. Retract the arm cylinder and lift the bucket off the ground. If oil flows out of the hose disconnected pipe ends and the boom cylinders are retracted at this time, oil leaks in the boom cylinders.
In case no oil flows out of the hose disconnected pipe ends but the boom cylinders are retracted, oil leaks in the control valve. T105-07-04-009 T5-7-71 YES Faulty pilot valve. YES Faulty corresponding Check if cylinder cylinder. drift is reduced when pilot shut-off Check if cylinder in- YES valve is closed. ternal leakage is found. Faulty corresponding control valve (damaged Check if correspond- NO spring or loose spool ing overload relief end). NO pressure is normal. · Refer to Operational Performance Test Faulty corresponding section for pressure NO overload relief valve. Faulty pilot valve. Faulty corresponding overload relief valve. NO Check if cylinder in- ternal leakage is YES found.