hitachi — PREPARATION FOR PERFORMANCE TESTS

TROUBLESHOOTING / Troubleshooting B T-3 Machine mistracks during combined opera- tion of travel and front attachment. Disconnect hose (SL). connecting to flow com- biner valve from signal control valve. Install a pressure gauge to signal control valve. Check if signal pressure is approx. 3.9 MPa (40 kgf/cm 2 , 570 psi). YES Faulty flow combiner valve control spool in signal control valve. NO Check load check valve for any abnor- mality. YES Faulty load check valve. Check flow combiner valve in control valve for any abnormality. NO Find out cause of trouble by tracing other trouble symptoms. NO Faulty flow combiner valve.

YES Signal Control Valve (Control Valve Side) Port SL T1J1-05-07-002 T5-7-80