TROUBLESHOOTING / Troubleshooting B Even if auto lubrication time is over, auto lubrication does not stop. Interval: 60 minutes (The interval setting can be changed between 10 and 90 minutes.), Lubricat- ing time: 5 minutes Even if auto lubrication switch is turned OFF, auto lubrication does not stop. Refer to “Even if auto lubrication time is over, auto lubrication does not stop.” Interval: 60 minutes (The interval setting can be changed between 10 and 90 minutes.), Lubricat- ing time: 5 minutes At the same time when the auto lubrication device stops, auto lubrication alarm is displayed. There is a possibility that the pressure cannot be increased to the required level within the set time.
In this case, check the following: ѕ Grease amount in the cartridge ѕ Air mixed into the circuit ѕ Plug at the cartridge ѕ Failure of the proximity switch mode · Auto lubrication switch: OFF · Key switch: ON Faulty MC, or refer to “Even if auto lubrication time is over, auto lubrica- tion does not stop.” Check if auto lubrica- tion alarm is dis- played. YES Faulty auto lubrication switch, or shorted circuit in harness between MC and auto lubrication switch. NO T5-7-90 YES Faulty auto lubrication re- lay (R11). Switch auto lubrication relay (R11) with other general relay. Check if YES Faulty MC. auto lubrication stops. Monitor auto lubrication switch. Check if “OFF” is dis- NO played.
Faulty auto lubrication · Monitor item: Lubrication NO switch. Faulty auto lubrication re- lay (R11). Faulty auto lubrication switch. NO Monitor auto lubrication switch. Check if “OFF” is dis- NO played.