TROUBLESHOOTING / Troubleshooting B Fault Code List T5-4-95 Location in Trouble Fault Code Cause Symptom Abnormal circulation air sensor E11 Broken circuit in air circulation sensor Y value (air flow-in temperature) cannot be adjusted in response to the set-temperature. E12 Short-circuited circulation air sensor Abnormal fresh air sensor E13 Broken circuit in fresh air sensor Operation is controlled under such cir- cumstance as no fresh air sensor is pro- vided. E14 Short-circuited fresh air sensor Abnormal solar radiation sensor E18 Short-circuited solar radiation sensor Operation is controlled under such cir- cumstance as no solar radiation sensor is provided.
Abnormal evapora- tor sensor E21 Broken circuit in evaporator sen- sor Operation is controlled under such cir- cumstance as the evaporator temperature is set to 10 °C (50 °F). E22 Short-circuited evaporator sen- sor Abnormal damper E43 Abnormal air vent damper Corresponding damper servo becomes inoperable. E44 Abnormal air mix damper E45 Abnormal circulation/fresh air damper Water temperature sensor E15 Broken circuit in water tempera- ture sensor Operation is controlled under such cir- cumstance as the water temperature is set to 60 °C (140 °F).
(Warm-up control is not performed.) E16 Short-circuited water tempera- ture sensor Abnormal refrigerant E51 Abnormal high/low refrigerant pressure The compressor clutch is disengaged. (The compressor stops.)