TROUBLESHOOTING / Troubleshooting B CHARGE AIR CONDITIONER WITH REFRIGERANT Necessity of Purging Make sure to purge the air conditioner circuit with a vacuum before charging with refrigerant (R134a) because the following problems can arise if air or other gases remain in the A/C circuit. 1. Pressure rise in the high pressure side: If air remains in the air conditioner circuit, this disturbs the heat exchange between refrigerant and air in the condenser, causing pressure to rise in the high pressure side (compressor side).

Usually, refrigerant gas is easily liquefied, however, air cannot be liquefied and remains as a gas in the condenser because the temperature at which air liquefies is extremely low. That is, liquidation of the refrigerant gas in the condenser decreases by the amount of air in the circuit, and the gas pressure in the high pressure side increases accordingly. 2. Metal corrosion: If air remains in the air conditioner circuit, a chemical reaction between refrigerant and moisture in the air takes place, and as a result, hydrochloric acid, that corrodes metals such as aluminum, copper and iron, is produced. 3. Plugging of the expansion valve by moisture:

When high pressure refrigerant gas passes through the expansion valve, gas pressure decreases and temperature drops. Moisture included in high pressure refrigerant gas in the air conditioner circuit freezes at the expansion valve orifice, plugging refrigerant flow. Operation of the air conditioner becomes unstable and cooling efficiency lowers. Air W115-02-10-001 Pressure increases if air remains in the air conditioner circuit. W115-02-10-002 corrodes metals if moisture exists. Metal Corrosion T5-4-107 hloric acid Hydrochloric Acid Plugged Refr Flow ced at the Plugged Refr Flow igerant valve disturbs t flow, lowering W115-02-1 ficiency. Low Cooling Efficiency Low Cooling Efficiency