TROUBLESHOOTING / Electrical System Inspection HOW TO TROUBLESHOOT ALTERNATOR MALFUNCTIONS In general, the alternator alarm remains off when the alternator is generating power. If the alternator alarm is displayed while the engine is running, the alternator might be defective. How to check the circuit 1. Stop the engine. Turn the key switch to the ON position. Confirm that the alternator indicator comes on. Monitor Unit 2. Measure the voltage between the B and the vehicle frame. If the measured voltage is around 24 V, the alternator circuit can be considered normal.
If the measured voltage is low, a shortage in battery capacity or looseness of the wire connectors of the alternator circuit might be the cause of the malfunction. When the voltage is 0 V, the wiring between the fuse box and alternator might be loose or disconnected. Also, the alternator cannot generate electricity if the ground line is disconnected. 3. Next, start the engine and measure the voltage generated while as the alternator rotates. As described above, measure the voltage between terminals B and the vehicle frame. If the voltage is around 28 V, the alternator is operating normally.
If the rated voltage is not being generated, there is some trouble with the alternator or the regula- tor. T1J1-05-01-007 Alternator Alarm Connector (L, R) B T16J-05-06-001 T5-8-7