hitachi — PREPARATION FOR PERFORMANCE TESTS

OPERATIONAL PERFORMANCE TEST / Standard T4-2-11 Item Reference Value Measured Value Remarks First Second Third Average PUMP 1 PUMP CONTROL PRESSURE (MPa) Control Lever in Neutral∗ Boom Raise∗ Boom Lower∗ Arm Roll-in∗ Arm Roll-Out∗ Bucket Roll-Out∗ Bucket Roll-In∗ Boom Raise + Arm Roll-In + Bucket Roll-In Combined Operation∗ 0.04 4.0 - 4.0 4.0 4.0 4.0 4.0 When relieving When relieving When relieving When relieving When relieving When relieving PUMP 2 PUMP CONTROL PRESSURE (MPa) ∗ Control Lever in Neutral ∗ Boom Raise ∗ Boom Lower ∗ Arm Roll-in ∗ Arm Roll-Out ∗ Bucket Roll-Out ∗ Bucket Roll-In Boom Raise + Arm Roll-In + Bucket Roll-In Combined ∗ Operation 0.04 4.0 - 4.0 4.0 0.04 0.04 4.0 When relieving When relieving When relieving When relieving When relieving When relieving PUMP 1 LOADING RATE (%) 25 When relieving Boom or Arm PUMP 2 LOADING RATE (%) 25 When relieving Boom or Arm