OPERATIONAL PERFORMANCE TEST / Standard T4-2-12 Item Reference Value Measured Value Remarks First Second Third Average Front Attachment Control Pressure (MPa)* 4.0 When relieving Travel Pilot Control Pressure (MPa)* 4.0 When relieving Boom Rise Pilot Control Pressure (MPa)* 4.0 When relieving Boom Lower Pilot Control Pressure (MPa)* 4.0 When relieving Arm Roll-In Pilot Control Pressure (MPa)* 4.0 When relieving Arm Roll-Out Pilot Control Pressure (MPa)* 4.0 When relieving Bucket Dump Pilot Control Pressure (MPa)* 4.0 When relieving Bucket Cloud Pilot Control Pressure (MPa)* 4.0 When relieving Swing Pilot Control Pressure (MPa)* 4.0 When relieving Travel (Left) Pilot Control Pressure (MPa)* 4.0 When relieving Travel (Right) Control Pres- sure (MPa)* 4.0 When relieving Auxiliary Pilot Control Pres- sure (MPa)* 4.0 When relieving Counter Weight Removal Pilot Control Pressure (MPa)* 4.0 When relieving Boom Cylinder Bottom Pressure (MPa)* 34.3 When Boom Rise relieving Power Boost Control Pres- sure (MPa) When Operating 2.15 Power Digging Switch:
ON, Lever Neutral When Boom Rise Relieving 2.15 Travel Motor Control Pres- sure (MPa) 4.0 When High Speed Traveling Boom Mode Control Pres- sure (MPa) Boom Mode Selector: ON Lever in Neutral 0 Boom Rise 3.23 When relieving Boom Flow Control Solenoid Valve Output Pressure (MPa) Lever in Neutral 0 Combined Operation with Boom Lower and Arm Roll-In 4.0