Operator Cab And Controls - Section 32 9/09 OM3232 Page 32-22 VEHICLE HEALTH MONITORING SYSTEM (VHMS) During normal truck operation, the red LED digits on the VHMS controller will count from 1-99 continuously. Operation This system uses the VHMS controller (2, Figure 32- 10) to gather data about the operation of the truck from sensors and other controllers installed on the truck. The data stored in the VHMS controller is downloaded by computer using VHMS diagnostic port (6, Figure 32-4) or transmitted directly by communications satellite utilizing Orbcomm controller (1, Figure 32-10). This data is then compiled at the Komatsu computer server.
Based on this information, the servicing Komatsu distributor will suggest improvements and provide information aimed at reducing machine repair costs and downtime. When the key switch is turned to OFF, the VHMS controller will remain on while it finishes processing internal data and saves the recent data into permanent memory. When the data has been safely stored, the two digit LED display will turn off. This process could take up to three minutes to complete. If 24V power is disconnected (using the battery disconnect switches) from the VHMS controller before it has completed its shutdown procedure, the VHMS controller will lose all data gathered since the key switch was last turned to ON.
Do not disconnect battery power until the VHMS controller has completed the shutdown procedure and has turned the LED digits off. When data store button (1, Figure 32-9) on the rear of the center console is pressed, it will store a “snapshot” of the SIBAS drive system. It will also trigger VHMS to store a snapshot of the truck operating system. A “snapshot in progress” message will be displayed on the speedometer/digital display while VHMS is recording the snapshot. VHMS is turned on by the truck key switch. Immediately after receiving 24V power from the key switch, the VHMS controller begins the power-up initialization sequence.
This sequence takes about three seconds, during which time red LED digits (3, Figure 32-10) near the top of the VHMS controller will display a circular sequence of flashing LED segments. FIGURE 32-10. VHMS COMPONENT LOCATION (R.H. WALL OF AUXILIARY CONTROL CABINET) 1. Orbcomm Controller 2. VHMS Controller 3. Red LED Digits FIGURE 32-9. REAR OF CENTER CONSOLE 1. Data Store Button