Komatsu — Unloader Valve

OM4214 Automatic Lubrication System - Section 42 Page 42-3 SYSTEM COMPONENTS Flow control valve (10, Figure 42-1), mounted on the manifold, controls the amount of oil flow to the hydraulic motor. The flow control valve has been factory adjusted and the setting should not be disturbed. Flow Control Valve Filter Filter assembly (21, Figure 42-2), mounted on the grease reservoir, filters the grease prior to refilling the reservoir from the shop supply. A bypass indicator alerts service personnel when the filter requires replacement. Solenoid Valve Hydraulic Motor and Pump Solenoid valve (5, Figure 42-1), when energized, allows oil to flow to the hydraulic motor.

Rotary hydraulic pump (3 and 9, Figure 42-1) is a fully hydraulically-operated grease pump. An integrated pump control manifold is incorporated with the motor to control input flow and pressure. Vent Valve With vent valve (7, Figure 42-1) closed, the pump continues to operate until maximum grease pressure is achieved. As this occurs, the vent valve opens and allows the grease pressure to drop to zero, so the injectors can recharge for their next output cycle. NOTE: The pump crankcase oil level must be maintained to the level of pipe plug (17, Figure 42-2). If necessary, refill with 10W-30 motor oil.

Lubrication Cycle Timer The solid state lubrication cycle timer provides a 24 VDC timed-interval signal to energize solenoid valve (3, Figure 42-3), providing oil flow to operate the grease pump motor. This timer is mounted in the Electrical Interface Cabinet. Hydraulic oil supply inlet pressure must not exceed 24 132 kPa (3,500 psi). Exceeding the rated pressure may result in damage to the system components and personal injury. Over Pressure Cut Off Switch Pressure switch (18, Figure 42-2) is a normally open switch set at 20 684 kPa (3,000 psi). This switch de- energizes the pump solenoid relay if the grease line pressure reaches the switch pressure setting, turning off the motor and pump.

Grease Reservoir Reservoir (12, Figure 42-1) has an approximate capacity of 41 kg (90 lbs.) of grease. When the grease supply is replenished by filling the system at the service center, the grease is passed through the filter to remove contaminants before it flows into the reservoir. Grease System Failure Switch Pressure switch (24, Figure 42-2) is a normally open switch set at 13 789 kPa (2,000 psi). This switch monitors grease pressure in the injector bank on the rear axle housing. If the appropriate grease pressure is not achieved during the normal pump cycle, the warning system will be activated.

The repair light will illuminate and a message will be displayed on the dash panel to notify the operator that a problem exists in the lubrication system. Pressure Reducing Valve Pressure reducing valve (4, Figure 42-1), located on the manifold, reduces the hydraulic supply pressure (from the truck steering circuit) to a suitable operating pressure for the hydraulic motor used to drive the lubricant pump. The pressure control valve has been factory adjusted and the setting should not be disturbed unless grease output pressure is outside the recommendations. Injectors Each injector (23, Figure 42-2) delivers a controlled amount of pressurized lubricant to a designated lube point.

Refer to Figure 42-2 for locations. A pressure gauge can be installed where pipe plug (8, Figure 42-1) is located. The pressure gauge will indicate hydraulic oil pressure to the inlet of the hydraulic motor. Normal pressure is 2241 - 2413 kPa (325 - 350 psi). Unloader Valve Unloader valve (14, Figure 42-3) protects the pump from high pressures. This relief valve is set at 27 580 kPa (4,000 psi).