Komatsu — Haul Cycle Warning Flags

OM6012 Payload Meter III - Section 60 Page 60-9 HAUL CYCLE DATA PLMIII records and stores data in its on-board flash memory. This memory does not require a separate battery. The data is available through the download software. C: No Final Load This message is generated when the payload meter is unable to determine the final payload in the truck. Typically, this means that the payload meter switched from a loaded state to the dumping state before the load could be accurately measured. PLMIII can store 5208 payload records. When the memory is full, the payload meter will erase the oldest 745 payload records and continue recording. D:

Maneuvering to Dumping Transition PLMIII can store 512 alarm records. When the memory is full, the payload meter will erase the oldest 312 alarm records and continue recording. This message is generated when the payload meter senses a body-up input during the maneuvering or repositioning process indicating that the operator has dumped the load. It may also be generated if the body-up signal is not properly reaching the payload meter and the weight in the truck falls dramatically while the truck is maneuvering or repositioning. All data is calculated and stored in metric units within the payload meter. The data is downloaded and stored in metric units within the Paradox database on the PC.

The analysis program converts units for displays, graphs and reports. E: Average Load or Tare Used This message indicates that the recorded payload may not be as accurate as a typical final load calculation. Typically, this is recorded when loading begins before an accurate tare is calculated or the load is dumped before the load can be accurately measured. The units noted in the Table 1 are the actual units stored in the data file. The value for the haul cycle start time is the number of seconds since January 1, 1970 to the start of the haul cycle. All other event times are referenced in seconds since the haul cycle start time.

The PC download and analysis program converts these numbers into dates and times for graphs and reports. F: Final Zone to Dumping Transition This message is generated when the payload meter senses a body-up while it is calculating the final payload indicating that the operator has dumped the load. It may also be generated if the body-up signal is not properly reaching the payload meter and the weight in the truck falls dramatically while the truck is calculating the final payload. Haul Cycle Warning Flags The payload meter expects haul cycles to progress in a particular way. When something unexpected takes place, the system records a warning flag.

Several events within the haul cycle can cause a warning flag to be generated. Each one indicates an unusual occurrence during the haul cycle. They do not necessarily indicate a problem with the payload meter or payload calculation. H: False Body Up This message indicates that the body was raised during the haul cycle without the load being dumped. The body-up signal indicated that the truck was dumping, but the weight of the truck did not fall below 20% of the rated load. A: Continuous Loading This message is generated when the truck is loaded over 50% full without the payload meter sensing swingloads. This indicates that a continuous loading operation was used to load the truck.

It may also indicate that the payload meter did not receive the brake lock input while the truck was being loaded. There may be a problem with the wiring or the brake lock was not used. The payload meter will not measure swingloads unless the brake lock is used during the loading process. I: Body Up Signal Failed This message indicates that the load was dumped without a body-up signal being received by the payload meter. The weight of the truck fell below 20%, but the payload meter did not receive a body- up signal from the sensor. J: Speed Sensor Failed B: Loading to Dumping Transition This message is generated when the payload meter senses a body up input during the loading process.

This message is usually accompanied by a no_final_load flag. This message indicates that the payload meter sensed the truck loading and dumping without receiving a speed signal.