MAINTENANCE MAINTENANCE PROCEDURE WHEN REQUIRED CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT G If inspection, cleaning, or maintenance is carried out with the engine running, dirt will get into the engine and the engine will suffer damage. Always stop the engine before carrying out these opera- tions. G When using compressed air, there is danger that dirt may be blown around and cause serious injury. Always use safety glasses, dust mask, and other protective equipment. Cleaning the outer element 1. Open the engine hood at the rear of the machine, loosen clip (2), remove dust cup (3). 2. Throw away the dust inside dust cup (3) and clean the inside of the cup. 3.
Take out element (4) and cover the air connector at the end of the air cleaner body with a clean cloth or tape. 4. Clean interior of the air cleaner body. 5. Direct dry compressed air (less than 0.69MPa (7kg/cm 2 , 100 PSI)) to the element from inside along its folds, then direct it from outside along its folds and again from inside. 1) Replace the element which has been cleaned 6 times repeatedly or used throughout a year. 2) Replace element when the dust indicator red piston appears soon after installing the cleaned element even though it has not been cleaned 6 times. 4-21 WARNING