Komatsu — CHECK,CLEAN AND REPLACE AIR CLEANER ELEMENT

MAINTENANCE PROCEDURE MAINTENANCE 6. If small holes or thinner parts are found on the element when it is checked by shining a light through it after cleaning, replace the element. NOTICE When cleaning the element, do not hit it or beat it against something. Do not use an element whose folds or gasket or seal are damaged. Wrap unused element and store them in a dry place. 7. Remove the clothe or taps used as a cover in Step 3. 8. Set the cleaned element (4) in position. 9. Set dust cup (3) with the arow pointing up, then set it to the air cleaner body and secure it with clip (2). 10. Press the button of dust indicator (1) to return the red pis- ton to its original position. 4-22