MAINTENANCE PROCEDURE MAINTENANCE 13. Drain the cooling water inside sub-tank (5), clean the inside of the sub-tank, then fill again with cooling water to a point midway betwee the FULL and LOW marks. 14. Stop the engine. About 3 minutes later, supply city water up to the water filler, then close radiator cap. CHECK BATTERY ELECTROLYTE LEVEL Carry out this check before operating the machine. G Do not use the battery if the battery electrolyte level is below the LOWER LEVEL line. This will accel- erate deterioration of the inside of the battery and reduce the service life of the battery. In addition, it may also cause an explosion.
G The battery generates flammable gas and there is danger of explosion, so do not bring fire or sparks near the battery. G Battery electrolyte is dangerous. If it gets in your eyes or on your skin, wash it off with large amount of water and consult a doctor. G When adding distilled water to the battery, do not allow the battery electrolyte to go above the UPPER LEVEL line. If the electrolyte level is too high, it may leak and cause damage to the paint surface or corrode other parts. NOTICE When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing.
Inspect the battery electrolyte level at least once a month and follow the basic safety procedures given below. 4-26 WARNING