Komatsu — BEFORE STARTING ENGINE

OPERATION MACHINE OPERATIONS AND CONTROLS CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL When removing the oil filler cap, oil may spurt out, so turn the cap slowly to release the internal pressure before removing the cap. 1. If the work equipment is not in the condition shown in the diagram on the right, start the engine, run the engine at low speed, retract the arm and bucket cylinders, then lower the boom, set the bucket teeth in contact with the ground, and stop the engine. 2. Open the door of the pump room on the right side of the machine and check sight gauge (G). The oil level should be between the H and L lines. NOTICE Do not add oil if the lebel is above the H line.

This will dam- age the hydraulic equipment and cause the oil to spurt out. 3. If the oil level is below the L line, add oil through oil filler (F) at the top of the hydraulic tank. REMARK The oil level will vary depending upon the oil temperature. Accordingly, use the following as a guide: G Before operation: around L level (Oil temperature 10 to 30єC (50 to 86єF)) G Normal operation: around H level (Oil temperature 50 to 80єC (122 to 176єF)) 3-25 WARNING