Komatsu — EVERY 500 HOURS MAINTENANCE

. MAINTENANCE MAINTENANCE PROCEDURE REPLACE HYDRAULIC OIL FILTER ELEMENT WARNING engine is stopped, and may cause burns. Wait for the 4 - 59 temperat ure to go down before sta When rem oving the oil filler cap, tu rn it slowly to release the i ntern 1. Remov e the cap from oil filler (F), and release the internal re. 4 bolts, then remove cover (1). internal pressu 2. Loosen 4 bolts, then remove When d oing this, the cover ma y fly out under the force of spring (2), hol d the cover down whe n removing the bolts. ve (3) and strainer (5), take out 3. After re moving spring (2), val t (4).

elemen If the (5), elemen If the re are metal particles or foreign material inside strainer contact your Komatsu distributor. ushing oil. 4. Clean t he removed parts in fl 5. Install t he new element in the place where old element (4) was installe d. 6. Set val ve (3), strainer (5) and spring (2) on top of the e lement. 7. Set cov er (1) in position, push it down by hand, and in stall the cover w ith the mounting bolts . (F). ngine according to "STARTING 8. Install t he cap of oil filler port 9. To ble ed the air, start the e ENGIN E (PAGE 3-87)" and run the engine at low idle for 10 s. e engine. minute 10.

Stop th take out REMARK Operate th e machine after halting for more than 5 minute s to e liminate bubbles in the oil i 11. Check for oil leakage and wip