TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11404 valve unit (SG) (relief pressure control). · Between terminal #A17 of connector MC-A in MC and terminal #2 of connector in solenoid valve unit (SG) (relief pressure control). Connector (Harness end of connector viewed from the open side) MC Connector MC-A T183-05-04-008 Solenoid Valve Unit (SG) (Relief Pressure Control) T1V1-05-04-003 T5-6-88 Fault Code Trouble Cause Influenced Control 11404-2 Abnormal Current Feedback of Solenoid Valve Unit (SG) (Relief Pressure Control) Current:
Both of Higher than 920mA or Less than 60 mA • Power Digging Control • Auto-Power Lift Control 11404-3 Abnormal Feedback High Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current: Higher than 920mA • Power Digging Control • Auto-Power Lift Control 11404-4 Abnormal Feedback Low Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current: Less than 56 mA • Power Digging Control • Auto-Power Lift Control Switch connectors of Faulty solenoid valve unit NO solenoid valve unit (SG) (SG) (relief pressure (relief pressure control) control). YES and other solenoid valve unit (SF, SC or SI). Faulty MC.
Check if fault code in switched solenoid valve YES Check for continuity in unit is displayed. harness between MC and solenoid valve unit (SG) (relief pressure control). · Between terminal #A11 of connector MC-A in Open circuit in harness. MC and terminal #1 of NO connector in solenoid Faulty solenoid valve unit (SG) (relief pressure control). Open circuit in harness. NO #A17 #A11