TROUBLESHOOTING / Troubleshooting A MONITOR UNIT FAULT CODE 13310 Coolant Temperature Sensor Connector (Harness end of connector viewed from the open end) Monitor Unit Connector Monitor-C #C8 T5-6-118 Fault Code Trouble Remedy 13310-2 Shorted Circuit in Coolant Temperature Sensor Check the coolant temperature sensor and harness. With terminal of coolant Shorted circuit in harness temperature sensor YES between monitor unit and disconnected, disconnect sensor. connector monitor-C in YES monitor unit. Check for continuity between terminal #C8 of harness end Faulty monitor unit. Check if resistance of of connector in monitor unit NO coolant temperature and machine. sensor is specification.
Faulty coolant temperature NO sensor. Faulty coolant temperature sensor. NO Coolant Temperature (゚C) Resistance (kΩ) 25 7.6±0.76 40 4.0±0.35 50 2.7±0.22 80 0.92±0.07 95 0.56±0.04 105 0.42±0.03 120 0.28±0.01 · · 6 · · · · 1 · 1 · · · · · 7 #