TROUBLESHOOTING / Troubleshooting A MONITOR UNIT FAULT CODE 13311 Fuel Level Sensor Float FULL R370 257 mm 3/4 93 mm 70.5 mm Connector (Harness end of connector viewed from the open end) 204 mm 1/2 338 mm 1/4 Fuel Sensor EMPTY 2 1 T178-05-05-001 T5-6-119 Fault Code Trouble Remedy 13311-3 Shorted Circuit in Fuel Level Sensor Check the fuel level sensor and harness. 13311-4 Open Circuit in Fuel Level Sensor Check the fuel level sensor and harness. Shorted circuit in harness YES between monitor unit and With connector of fuel sensor. level sensor disconnected, disconnect connector monitor-C in YES monitor unit.
Connect terminal #1 of Check for continuity between terminal #C2 of harness end of YES Faulty monitor unit. connector in fuel level harness end of sensor to machine. connector in monitor unit Check for continuity and machine. Check if resistance of NO between terminal #C2 of fuel level sensor is harness end of Open circuit in harness specification. connector in monitor unit NO between monitor unit and and machine. sensor. Faulty fuel level sensor. NO Shorted circuit in harness between monitor unit and sensor. Faulty fuel level sensor. NO YES Faulty monitor unit.
Float Position Resistance (Ω) Upper Limit (FULL) 10+0 -4 3/4 26 1/2 38±5 1/4 53 Alarm Level 85±3 Lower Limit (EMPTY) 90+10 -0 Monitor Unit Connector Moniter-C · 6 · 1 · · · · 1 · · 7 · 6 · · · · 1 · 1 · · · · · 7