hitachi — FRONT ATTACHMENT SYSTEM TROUBLESHOOTING

TROUBLESHOOTING / Troubleshooting B FRONT ATTACHMENT SYSTEM TROU- BLESHOOTING F-1 All front attachment actuator power is weak. Related MC Fault Code: None In case operating speeds are extremely slow, pump control may be malfunctioning (A-3 and/or A-4). Faulty pilot system may also cause this trou- ble. 34.3 to 36.3 MPa (350 to 370 kgf/cm 2 ) Main relief valve should be normal. Find out cause of trouble by tracing other trouble symptoms. Monitor pump 1 and 2 deliv- ery pressures. · Monitor item: Pump 1 and 2 de- livery pressure · Possible to display by service menu and monitoring in monitor unit. · Relieve boom, arm and bucket circuits. · Power mode switch: OFF · Work mode:

Digging Adjust main relief valve. Less than 34.3 MPa (Less than 350 kgf/cm 2 ) T5-7-100