TROUBLESHOOTING / Troubleshooting B F-2 Even if power digging switch is pushed, power does not increase. Boom raise power is weak when digging. Related MC fault Code: 11404-2, 11404-3, 11404-4 Refer to the pages for the SYSTEM / Control System group / Power Digging Control and Auto-Power Lift Control in the T/M (Operational Principle). Check the wiring connections first. YES Faulty solenoid valve unit (SG), or open circuit in harness between sole- noid valve unit (SG) and Pressure increases. Less than 34.3 MPa (350 kgf/cm 2 ) 36.5 MPa (370 kgf/cm 2 ) Check if fault code is displayed. Normal (HP mode may be confused.) · Fault code:
11404-2, 11404-3, 11404-4 YES Pump 1 and 2 pressures · Possible to display by service menu and monitoring in monitor unit. · Push power dig- ging switch and check pump pres- sure change with in 8 seconds. Faulty main relief valve. Monitor power digging switch. Push power digging switch. Check if “Pd” is changed. Pressure does not increase. Faulty power digging switch, or open circuit in harness between power digging switch and MC. NO · Monitor item: Power digging switch · In case boom raise power is weak during digging, go to YES. T5-7-101 Monitor pump 1 and 2 delivery pMreosnsituorre iste. m: NO ·