Cooling System Install Thermostats IMPORTANT: Top thermostat has a vent notch with wiggle wire (A) for air bleeding. Bottom thermostat has a blocking poppet that opens passage to radiator when coolant warms. 02 070 12 RG8242B –UN–05DEC97 1. Clean all material from thermostat cover and housing mounting surfaces. 2. Install smaller (non-blocking) thermostat in top position with vent (wiggle wire) at 12 o’clock position. Install larger blocking thermostat in bottom position. Install Thermostats 3. Install thermostat cover using a new gasket or seal (B). 4. If equipped, install M10 x 35 cap screw (C) securing thermostat cover-to-housing and tighten to specifications.
RG8239B –UN–05DEC97 Specification Thermostat Cover-to-Housing M10 x 35 Cap Screw—Torque 35 (26 lb-ft) ....................................... 5. Install and tighten thermostat cover/housing assembly-to-block cap screws to specifications. Thermostat Cover Installed Specification Thermostat Cover/Housing Assembly-to-Block Cap Screws— Torque 50 (37 lb-ft) ............................................................................. A—Wiggle Wire B—Gasket C—M10 x 35 Cap Screw RG,RG34710,233 –19–24SEP02–1/1 CTM100 (06APR04) 02-070-12 P OWER T ECH 10.5 L & 12.5 L Diesel Engines 040604 PN=296