Delphi — Test Thermostat Opening Temperature

CTM100 (06APR04) 02-070-13 P OWER T ECH 10.5 L & 12.5 L Diesel Engines 040604 PN=297 Cooling System Test Thermostat Opening Temperature 1. Remove thermostats. (See REMOVE THERMOSTATS earlier in this group.) CAUTION: DO NOT allow thermostat or thermometer to rest against the side or bottom of container when heating water. Either may rupture if overheated. 2. Visually inspect thermostats for corrosion or damage. Replace thermostats as a matched set as necessary. 3. Suspend thermostats and a thermometer in a container of water. –UN–23NOV97 4. Stir the water as it heats. Observe opening action of thermostat and compare temperatures with specification given in chart below.

RG5971 Specification Thermostat Test—Rating...................................................... 82°C (180°F) Testing Thermostats Initial Opening (Range) Temperature......................................................... 80—84°C (175—182°F) Full Open (Nominal) Temperature........................................ 94°C (202°F) NOTE: Due to varying tolerances of different supplies, initial opening and full open temperatures may vary slightly from specified temperatures. 5. Remove thermostat and observe its closing action as it cools. In ambient air the thermostat should close completely. Closing action should be smooth and slow. 6. If any one thermostat is defective, replace both thermostats.

RG,RG34710,234 –19–30SEP97–1/1 02 070 13