TM2361 (24JUN08) 9015-15-4 450DLC Excavator Operation and Tests 062608 PN=448 Sub-System Diagnostics Starting Circuit—The starting circuit consists of the Once the engine is running, alternator output voltage is following components: routed to the starter protection relay (K18) terminal R. When alternator output voltage reaches 21—22 volts, • Batteries (G1 and G2) the starter protection relay disconnects terminal B from • Battery relay (K19) terminal C, removing power from starter motor (M1). • Starter motor (M1) The starter motor will then stop cranking engine or • Key switch (S1) prevent it from engaging if the engine is running and • Starter relay (K4) the alternator is producing power.
• Starter relay diode (V5) • Starter protection relay (K18) When a warning alarm or security code error is • Engine stop switch (S14) detected, the monitor controller (A4) pin A4 is • Security relay (K5) connected to ground, energizing starter relay (K4) and • Security diode (V4) security relay (K5). Energizing starter relay removes • Pilot shutoff switches (S3 and S4) power from starter protection relay (K18) terminal S. • Pilot shutoff diode (V8) With starter protection relay de-energized, current is • Engine control module (ECM) (A1) not supplied to starter motor (M1) terminal C, • Engine control module (ECM) relay (K14) preventing engine from starting.
When key switch (S1) is moved to the START position, When pilot control lever is in the forward (unlocked) power is applied from key switch terminal ST to position, pilot shutoff switches 1 and 2 (S3 and S4) are terminals 1 and 3 of starter relay (K4). Key switch closed. With switches closed, starter relay (K4) 9015 15 4 terminal M also receives power, energizing battery terminal 2 is connected to ground, energizing starter relay (K19). The energized battery relay supplies relay and removing power from starter motor (M1) power to starter motor (M1) terminal B through terminal C. This prevents activation of the starter motor terminals A and B on battery relay.
Battery relay also when pilot control lever is in the down (unlocked) supplies power to starter protection relay (K18) position. terminal B. Security diode (V4), starter relay diode (V5), and pilot De-energized starter relay (K4) supplies power from shutoff diode (V8) are used to prevent backfeeding. terminal 4 to starter protection relay (K18) terminal S, energizing starter protection relay.
Once energized, Charging Circuit—The charging circuit consists of terminals B and C are internally connected within batteries (G1 and G2), battery relay (K19), battery starter protection relay, which supplies power from relay diode (V2), key switch (S1), alternator (G3), load terminal C to starter motor (M1) terminal C. Starter dump relay (K1), load dump relay diode (V3), and motor (M1) then cranks the engine. monitor controller (A4).
Power from key switch terminal M is also supplied With key switch (S1) in the ON position, battery power through fuse (F18) to main controller (MCF) (A3), is applied through load dump relay diode (V3) to monitor controller (A4), information controller (ICF) battery relay (K19), energizing the relay. With engine (A5), and ECM (A1). After ECM receives power, ECM running, the alternator (G3) begins to produce output energizes ECM relay (K14). With relay energized, voltage.
Output voltage from alternator terminal B+ is power is supplied from batteries (G1 and G2) through routed through the energized battery relay, charging fuse (F10), ECM relay (K14), and fuse (F14) to fuel batteries (G1 and G2). pump control valve solenoids 1 and 2 (Y15 and Y16), and then to ECM. Continued on next page LD30992,000020D –19–27APR06–2/3