TM2361 (24JUN08) 9015-15-24 450DLC Excavator Operation and Tests 062608 PN=468 Sub-System Diagnostics Pump Flow Rate Control: The pump flow rate control signal to the pump control solenoids, the pump servo provides oil as needed from the main pumps to the piston shifts to increase the pump swash plate angle, hydraulic circuit being controlled relative to movement and thus increase the pump delivery output. For of the control lever. When the control lever is moved, hydraulic information on pump regulation, see Pump 1 pilot control pressure acts on the pressure sensor and 2 Regulator Operation. (Group 9025-05.) located in the pilot circuit being operated.
The pressure sensor detects this pressure and sends a signal to the NOTE: When activating the boom down circuit, the MCF. MCF does not use the signal from the boom down pressure sensor (B53) to vary pump flow MCF inputs involved (pilot circuit sensors): rate. The pump swash plate angle does not change because the boom lowers mostly by its • Swing pressure sensor (B33) own weight with the help of the boom • Arm out pressure sensor (B50) regenerative valve. For information on the • Arm in pressure sensor (B51) boom regenerative valve, see Boom • Boom up pressure sensor (B52) Regenerative Valve Circuit Operation.
(Group • Bucket curl pressure sensor (B54) 9025-05.) • Bucket dump pressure sensor (B55) • Travel right pressure sensor (B56) When the control lever is moved back to neutral, the • Travel left pressure sensor (B57) pressure sensor of the pilot circuit that was activated detects no pressure in the pilot circuit and sends a MCF inputs involved (pump pressure sensors): corresponding signal back to the MCF. The MCF 9015 15 24 compares the signals from pump control pressure • Pump 1 control pressure sensor (B36) sensors (B36 and B38) with the signal from the pilot • Pump 2 control pressure sensor (B38) circuit pressure sensors to calculate the oil amount needed.
Since no hydraulic circuits are being actuated MCF outputs involved: at this time, the MCF sends a signal to the pump control solenoids (Y12 and/or Y13) to decrease swash • Pump 1 control solenoid (Y12) plate angle to minimum, causing the pump delivery • Pump 2 control solenoid (Y13) flow to go to minimum. The MCF determines the actual angle of the swash Engine Speed Sensing Control: With engine speed plates in pumps 1 and 2 by signals provided by pump sensing control, the MCF controls pump flow rate in 1 control pressure sensor (B36) (terminal D11) and response to engine speed changes due to varying pump 2 control pressure sensor (B38) (terminal D4). loads on the engine.
This provides a more efficient engine output and prevents engine from stalling when The MCF compares the signal from pump control operating in adverse conditions such as at high pressure sensors (B36 and B38) with the signal from altitude. the pressure sensor of the pilot circuit being operated to calculate the oil amount needed. The MCF then MCF input involved: Engine speed dial (R15) sends a pulse width modulated (PWM) signal out terminals A16 and A22 to energize pump 1 control MCF outputs involved: solenoid (Y12). It also sends a PWM signal out terminals A19 and A30 to energize pump 2 control • Pump 1 control solenoid (Y12) solenoid (Y13).
When the MCF increases the current • Pump 2 control solenoid (Y13) Continued on next page CS33148,00008EB –19–28APR06–7/15