John Deere 450DLC — Main Controller (MCF) Circuit Theory of Operation

TM2361 (24JUN08) 9015-15-25 450DLC Excavator Operation and Tests 062608 PN=469 Sub-System Diagnostics The engine target speed is set by the engine speed Y13) to reduce swash plate angle on pumps 1 and 2 dial, which sends a corresponding signal to terminal by 15 percent, which in turn, decreases the pump flow D15 on the MCF. The engine control module (ECM) rate. communicates the actual engine speed to the MCF through the CAN data link. For information on the When in E mode, the MCF will also send a signal to ECM, see Engine Control Module Theory of Operation. the ECM to limit the engine target speed to a (Group 9015-15.) maximum of 1580 rpm to reduce fuel consumption.

See Engine Control—Power Mode Control previously The MCF compares the actual engine speed to the in this theory of operation. engine target speed, and if the load on the engine causes the actual engine speed to decrease less than Horsepower Control: The MCF controls pump flow rate the target speed, the MCF sends a signal to pump of pumps 1 and 2 so that the total torque of the two control solenoids (Y12 and Y13) to reduce the swash main pumps AND the fan pump does not exceed the plate angle on pumps 1 and 2, which decreases the engine output torque. pump delivery flow rate. MCF inputs involved: As the load on the engine lessens, the actual engine speed will increase.

When this happens, the MCF • Pump 1 delivery pressure sensor (B35) sends a signal to pump control solenoids (Y12 and • Pump 1 control pressure sensor (B36) Y13) to increase the swash plate angle on pumps 1 • Pump 2 delivery pressure sensor (B37) and 2, which increases the pump flow rate. • Pump 2 control pressure sensor (B38) NOTE: If in HP mode and the actual engine speed MCF outputs involved: increases to more than the target speed, the MCF will continue increasing the swash plate • Pump 1 control solenoid (Y12) angle during this time. The MCF will only do • Pump 2 control solenoid (Y13) this when HP mode is selected. The MCF compares the signals from pumps 1 and 2 E Mode Control:

Provides better fuel efficiency by delivery pressure sensors (B35 and B37) (terminals C3 reducing load on the engine and prevents engine from and C12) with the fan pump flow rate calculation (see stalling when operating in adverse conditions such as Fan Pump Flow Control later in this theory of at high altitude. operation) to calculate the maximum target pump displacement (swash plate angle) on pumps 1 and 2. MCF input involved: Power mode switch (S12) NOTE: The MCF does not use horsepower control to MCF outputs involved: change the fan pump swash plate angle. Fan control is done strictly by the fan pump flow • Pump 1 control solenoid (Y12) rate control.

See Fan Pump Flow Control later • Pump 2 control solenoid (Y13) in this theory of operation. • ECM (through CAN) The MCF determines actual pump displacement When power mode switch (S12) is at the E position, (swash plate angle) of pumps 1 and 2 by signals from the power mode switch provides a ground to terminal pump control pressure sensors (B36 and B38) B6 on the MCF. When the MCF detects this ground, (terminals D11 and D4). the MCF sends a signal to pump solenoids (Y12 and Continued on next page CS33148,00008EB –19–28APR06–8/15 9015 15 25