References Travel Right Pressure Sensor (B56)—Voltage 4.5—5.5 volts ..................................................................... Travel Left Pressure Sensor (B57)—Voltage 4.5—5.5 volts ..................................................................... 3. If voltage is lower or no voltage is present, check wiring. See Machine Harness (W2) Wiring Diagram, See Control Valve Harness (W7) Wiring Diagram, and See Pump Harness (W8) Wiring Diagram. (Group 9015-10.) LD30992,000022A –19–14MAR06–3/3 TM2361 (24JUN08) 9015-20-97 450DLC Excavator Operation and Tests 062608 PN=587 Solenoid Test 1. A suspect solenoid can be checked by switching positions with a known good solenoid.
If the problem follows the suspect solenoid, it has failed. If the problem remains, the harness has failed. 2. To check a solenoid using an ohmmeter, remove it from the machine. 3. Measure resistance as indicated. Resistance may vary from one solenoid to another. Specification Pilot Shut-Off Solenoid (Y10)— Resistance............................................................................. 42—58 ohms LD30992,000022B –19–14MAR06–1/1 9015 20 97