TM2361 (24JUN08) 9015-20-98 450DLC Excavator Operation and Tests 062608 PN=588 References Proportional Solenoid Test 1. A suspect solenoid can be checked by switching positions with a known good solenoid. If the problem follows the suspect solenoid, it has failed. If the problem remains, the harness has failed. 2. To check a solenoid using an ohmmeter, remove it from the machine. 3. Measure resistance as indicated. Resistance may vary from one solenoid to another. Main Controller Solenoids—Specification Boom Flow Rate Solenoid (Y22) (SF)—Resistance..................................................................
20—30 ohms Boom Mode Solenoid (Y23) (SC)—Resistance.................................................................. 20—30 ohms Power Dig Solenoid (Y24) (SG)— Resistance............................................................................. 20—30 ohms Travel Speed Solenoid (Y25) 9015 20 98 (SI)—Resistance.................................................................... 20—30 ohms Pump 1 (4-Spool) Control Solenoid—Resistance........................................................... 14—21 ohms Pump 2 (5-Spool) Control Solenoid—Resistance...........................................................
14—21 ohms Fan Pump Control Solenoid— Resistance............................................................................. 14—21 ohms LD30992,000022C –19–17APR06–1/1