John Deere 450DLC — Install DEUTSCH™ Contact

Install DEUTSCH Contact 1. Strip 6 mm (1/4 in.) insulation from wire. 2. Adjust selector (A) on JDG360 Crimper for correct wire size. TS117 –UN–23AUG88 3. Loosen lock nut (B) and turn adjusting screw (C) in until it stops. DEUTSCH is a trademark of the Deutsch Co. LD30992,000023F –19–31MAR06–1/4 IMPORTANT: Select proper size contact "sleeve" or "pin" to fit connector body. 4. Insert contact (A) and turn adjusting screw (D) until contact is flush with cover (B). TS0134 –UN–23AUG88 5. Tighten lock nut (C). Continued on next page LD30992,000023F –19–31MAR06–2/4 TM2361 (24JUN08) 9015-20-120 450DLC Excavator Operation and Tests 062608 PN=610 References 3.

Release primary locking latch (3) next to the pin to be removed using screwdriver on JDG1383 service tool. 4. Gently pull wire out from back of connector. 5. Replace connector contact as necessary. (See Install –UN–01MAY00 Connector Contact procedure.) 6. Install wire terminal back into connector until it clicks into place. T130689B NOTE: Locking wedge in 2-pin connector is not symmetrical. Position latch shoulder next to terminals. 7. Install locking wedge until it snaps into place. 3—Primary Locking Latches N–01MAY00 9015 20 ,120 –U T130690B LD30992,000023E –19–31MAR06–2/2