References IMPORTANT: Contact must remain centered between indentors while crimping. 6. Insert wire in contact and crimp until handle touches stop. 7. Release handle and remove contact. TS118 –UN–23AUG88 LD30992,000023F –19–31MAR06–3/4 Replace WEATHER PACK Connector IMPORTANT: Identify wire color locations with connector terminal letters. 1. Open connector body. TS0128 –UN–23AUG88 2. Insert JDG364 Extraction Tool over terminal contact in connector body. 3. Hold extractor tool fully seated and pull wire from connector body. NOTE: If terminal cannot be removed, insert wire or nail through extractor tool handle and push terminal contact from connector.
WEATHER PACK is a trademark of Packard Electric. Continued on next page LD30992,0000240 –19–31MAR06–1/2 TM2361 (24JUN08) 9015-20-121 450DLC Excavator Operation and Tests 062608 PN=611 IMPORTANT: If all wire strands are not crimped into contact, cut off wire at contact and repeat contact installation procedures. NOTE: Readjust crimping tool for each crimping procedure. G88 –UN–23AU 8. Inspect contact to be certain all wires are in crimped barrel. TS0135 LD30992,000023F –19–31MAR06–4/4 9015 20 ,121