References IMPORTANT: Carefully spread contact lances to assure good seating on connector body. NOTE: Connector bodies are "keyed" for proper contact mating. Be sure contacts are in proper alignment. TS0130 –UN–23AUG88 4. Push contact into new connector body until fully seated. 5. Pull on wire slightly to be certain contact is locked in place. 6. Transfer remaining wires to correct terminal in new connector. 7. Close connector body. LD30992,0000240 –19–31MAR06–2/2 TM2361 (24JUN08) 9015-20-122 450DLC Excavator Operation and Tests 062608 PN=612 Install WEATHER PACKContact NOTE: Cable seals are color coded for three sizes of wire:
• Green - 18 to 20 gauge wire –UN–23AUG88 • Gray - 14 to 16 gauge wire • Blue - 10 to 12 gauge wire 1. Slip correct size cable seal on wire. TS0136 2. Strip insulation from wire to expose 6 mm (1/4 in.) and align cable seal with edge of insulation. NOTE: Contacts have numbered identification for two sizes of wire: a) #15 for 14 to 16 gauge wire b) #19 for 18 to 20 gauge wire 3. Put proper size contact on wire and crimp in place with –UN–02NOV94 a "W" type crimp, using JDG783 Terminal Applicator. TS1623 WEATHER PACK is a trademark of Packard Electric. Continued on next page LD30992,0000241 –19–31MAR06–1/2 9015 20 ,122