Some Functions Cannot Be Operated or Are Slow, Travel And Swing Are Normal Diagnostic Procedure NOTE: If travel and swing are normal, the pilot pump pressure is assumed to be normal in this diagnostic procedure. –1/1 TM2361 (24JUN08) 9025-15-18 450DLC Excavator Operation and Tests 062608 PN=768 Diagnostic Information 3 Power Boost Pressure Check Key on, use monitor service menu to display Pump 1 or Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Put power mode switch on HP and work mode on digging. Run engine at fast idle and take arm-in function over relief. Record pressure. Push and hold power dig switch on control lever and observe monitor.
Does pump 1 and 2 delivery pressure increase approximately 2.5 MPa when power dig switch held on? YES: Diagnose problem in main controller. See Main Controller (MCF) Diagnostics Using Dr. ZX. (Group 9015-20.) NO: Replace or adjust main relief valve. See Main Relief and Power Digging Valve Test and Adjustment. (Group 9025-25.) – – –1/1 1 Actuating Pilot Pressure Check Key on, use monitor service menu to display Swing / Attachment Control Pilot Pressure. See Monitor Service Menu Operation. (Group 9015-16.) NOTE: Spool actuating pressure can be checked for each function by installing a tee and gauge in pilot line and then actuating that function.
Perform Control Valve Spool Actuating Pilot Pressure Test. (Group 9025-25.) Run engine at fast idle and operate problem function. Observe pressure when function held over relief. Is pilot pressure above 3.70 MPa? YES: Go to Pump Control Pressure Check. NO: If boom operation is abnormal, repair pilot valve or shockless valve spool. See Pilot Signal Manifold Disassemble and Assemble. (Group 3360.) – – –1/1 9025 15 18 2 Pump Control Pressure Check Key on, use monitor service menu to display Pump 1 and Pump 2 Control Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Run at fast idle and observe pressure on monitor as problem function control lever is moved slowly.
Does pump control pressure change smoothly when lever is slowly moved? YES: Go to Circuit Relief Valve Check. NO: Repair shuttle valve in pilot signal manifold. See Pilot Signal Manifold Disassemble and Assemble. (Group 3360.) – – –1/1