John Deere 450DLC — HP (High Power) Function Does Not Operate, P (Standard) Mode Is Normal Diagnostic Procedure

9025 15 30 TM2361 (24JUN08) 9025-15-30 450DLC Excavator Operation and Tests 062608 PN=780 Diagnostic Information 2 HP Engine Speed Check Key on, use monitor service menu to display Actual Engine Speed and Power Mode. See Monitor Service Menu Operation. (Group 9015-16.) Put power mode switch on P and work mode on digging. Run engine at fast idle and take arm-in function over relief. Record engine speed. Turn power mode switch to HP position. Does engine speed increase approximately 100 rpm when switch is moved to HP? YES: Go to Power Boost Pressure Check. NO: Select correct engine speed and power mode setting. See Engine Speed Control System Operation.

(Group 9010-05.) – – –1/1 3 Power Boost Pressure Check Key on, use monitor service menu to display Pump 1 or Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Put power mode switch on HP and work mode on digging. Run engine at fast idle and take arm-in function over relief. Record pressure. Push power dig switch on control lever and observe monitor. Does pump 1 and 2 delivery pressure increase approximately 2.5 MPa when power dig switch held on? YES: Diagnose problem in main controller. See Main Controller (MCF) Diagnostics Using Dr. ZX. (Group 9015-20.). NO: Replace or adjust main relief valve. See Main Relief and Power Digging Valve Test and Adjustment.

(Group 9025-25.) – – –1/1