Right Travel Does Not Move During Single Travel Operation Diagnostic Procedure NOTE: Pressure oil from pump 1 is also routed to the arm and boom cylinders, so these functions can move at slightly slower speed during single operation. In level crowd operation, pressure oil is routed to the arm before the boom, so that boom raise becomes very slow if at all. The following item can also cause this problem. The pump 1 flow rate is minimized due to a malfunction. This will cause the right travel motor and bucket cylinder to be very slow. IMPORTANT: All of the below symptoms must occur at same time to use this diagnostic procedure. Single bucket operation speed is slow.
Boom will not raised properly during arm level crowding operation. Precision control of hydraulic function cannot be performed. –1/1 TM2361 (24JUN08) 9025-15-40 450DLC Excavator Operation and Tests 062608 PN=790 Diagnostic Information 7 Pump 2 Control Solenoid Valve Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) Inspect pump 2 control solenoid for sticking. Is control solenoid in good working condition? YES: Diagnostic procedure complete. NO: Replace pump 2 control solenoid valve. – – –1/1 1 DTC Check See Reading Diagnostic Trouble Codes With Monitor Display.
(Group 9015-20.) See Reading Diagnostic Trouble Codes With Service ADVISORDiagnostic Application Do any DTC exist? YES: Diagnose and repair as required to clear displayed DTC. Diagnostic procedure complete. NO: Go to Pump 1 Delivery Pressure Check. – – –1/1 9025 15 40 2 Pump 1 Delivery Pressure Check Key on, use monitor service menu to display Pump 1 or Pump 2 Delivery Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Monitor pump 1 delivery pressure on monitor while doing all hydraulic functions except left travel and swing. Does pump 1 delivery pressure change when control lever is moved? YES: Go to Pump 1 Control Pressure Check. NO: Go to Right Travel Check. – – –1/1